Uw, Ug, Uf and the glazing edge: comparing window performance

Before comparing quotations, check which part of the window a thermal value describes. A glazing value and a value for the complete window cover different things. The frame, the edge of the glass and the dimensions of the proposed window also matter. These terms help you ask for a comparison that relates to your project.

Window diagram showing Uw for the complete window, Ug for the glazing, Uf for the frame and Ψg at the glazing-to-frame junction.
An explanatory diagram of thermal values, not a product section or a statement of Hohensee product performance.

What do Uw, Ug, Uf and Ψg mean?

Uw describes the complete window, Ug the glazing and Uf the frame. Under comparable conditions, a lower U-value means less heat passing through the assessed element for the same temperature difference. The subscript therefore matters as much as the number.

Ug describes the glazing without the effect of its junction with the frame. This additional edge effect needs to be included when assessing the complete window.

SymbolScopeUnit
UwComplete windowW/(m²·K)
UgGlazing, excluding the edge effectW/(m²·K)
UfFrameW/(m²·K)
ΨgAdditional thermal effect of the glazing-edge junctionW/(m·K)

Sources: ift Rosenheim — WA-08/3: przedmowa i spis treści · Passive House Institute — Window and Glazing U-values (2006)

How is the complete window Uw calculated?

Uw accounts for the areas of glass and frame, together with the additional heat flow along the glazing edge. It is not a simple average of two catalogue figures. For a single glazing type and frame type, the simplified relationship is:

Uw = (Ag × Ug + Af × Uf + lg × Ψg) / (Ag + Af).

Ag and Af are the glazing and frame areas; lg is the glazing-edge length. Different frame sections, several glazing fields or additional components require the relevant contributions to be set out separately. Changing dimensions and divisions can therefore change Uw even when the system name stays the same.

Sources: Passive House Institute — Window and Glazing U-values (2006) · Passive House Institute — Window Installation Systems, v2.0 (2020), §4.6–4.8

What does the glazing-edge thermal bridge describe?

The glazing-to-frame junction creates additional heat flow, described by the linear thermal transmittance Ψg. This is a characteristic of the junction involving the glass, spacer and frame profile. Its unit differs from the unit of Uw, so the figures cannot simply be added together.

A “warm-edge” spacer is intended to improve the thermal behaviour at the edge of the insulating glass unit. The description does not replace a Ψg value applicable to the particular combination. Glazing, frame geometry and glass insertion also affect the result. A spacer name alone cannot establish one universal improvement in Uw for every window.

Sources: ift Rosenheim — WA-08/3: przedmowa i spis treści · Passive House Institute — Window Installation Systems, v2.0 (2020), §4.6–4.8

How can you compare two quotations?

A reference-window value describes a particular construction under defined assumptions. Check whether both quotations use the same reference case or values for your actual order dimensions. The real areas of glazing and frame matter.

Ask for the same set of assumptions in both quotations:

  • Dimensions, number of leaves, opening arrangement and divisions matching the same drawing.
  • The same glazing specification and Ug, together with the stated frame profile and applicable Uf data.
  • The spacer and assumed Ψg, identifying the junction to which that value applies.
  • Uw for the complete window and whether it comes from a calculation, test or declaration for a reference construction.

Sources: ift Rosenheim — WA-08/3: przedmowa i spis treści · Passive House Institute — Window and Glazing U-values (2006)

What else needs checking?

The thermal bridge at the glass edge is different from the junction between the window frame and the wall. The latter depends on the installation detail and needs separate consideration in the junction assessment and building energy balance. PHI documentation explicitly distinguishes an uninstalled element from an installed one.

Uw describes heat transmission; it does not by itself establish air permeability or the home’s heating costs. Bring window drawings and building information to the selection discussion, and a frame-to-wall detail for the installation assessment. Performance values for an order should come from its documentation rather than a general guide.

Sources: Passive House Institute — Window Installation Systems, v2.0 (2020), §4.6–4.8

Sources and further reading

  1. ift Rosenheim — WA-08/3: przedmowa i spis treści
  2. Passive House Institute — Window and Glazing U-values (2006)
  3. Passive House Institute — Window Installation Systems, v2.0 (2020), §4.6–4.8